Previous | Calendar |
July |
2024 |
Next | ||
---|---|---|---|---|---|---|
Sunday | Monday | Tuesday | Wednesday | Thursday | Friday | Saturday |
30JD182 |
1JD183NOTE: Starting on 7/1/24, start paying for urquell sys admin requests (crafty penguins) |
2JD184Site Visit (SpB, HR): Details , Photos (29) Span cylinder at 1000 psi, N2 at 300 --> 1920 psi swapped N2; now using cc236580 (at 300 psi) with AP200; started cc301531 at 1920 psi from 10:00-10:15 MST, removed screens from OTT Pluvio sensors (tested them w/o screens and now they seem ok) NOTE: do not use pluvio1/pluvio2 data since Tue 6/25/24! from 11:30-12:00 MST, added span (ru000402, from LBL) and n2 gas cylinders (cc236580) to the ap200 system from 12:30-13:00 MST, moved ap200 temp sensor #8 from ap200 level to 21.5m SpB Prius cool and breezy; some rain in early morning |
3JD185 |
4JD186Independence Day |
5JD187 |
6JD188 |
7JD189power outage at C-1 between approx 9-12 MST (broken fuse for NEON); US-NR1 was fine after power came back up |
8JD190 |
9JD191from 13:15-13:45 MST, short power outage to repair broken fuse (by Xcel) at C-1 short rain shower in PM? |
10JD192 |
11JD193Dave from MRS reported that there is a break/short in the power feed to C-1 that supports higher up on the ridge and NEON; power at US-NR1 is still ok Hot |
12JD194at around 3:30 MST, there was a large power outage that affected Ned to Ward (and MRS) at around 13:00 MST, the power was restored the fast logger did not come back up (NCTC logger is also dropping many samples) at 15:45 MST, did ddn/dup to the nidas system to try and fix any issues (didn't seem to help) [p.s. about five min after ddn/dup, the fast logger DID start sending data...NCTC is still having some issues] [p.p.s., Dave from MRS reported that a marmot had gotten into a transformer box...and shorted some wires (and itself)] at 23:51 MST, the fast logger (ch. 30) stopped working again! Very Hot |
13JD195 |
14JD196 |
15JD197NOTE: the fast logger dropped 10-hz samples all weekend at around 9:00 MST, did ddn/dup to the nidas system to try and fix any issues at around 11:00 MST, rebooted isffa to try and cleanup the fast logger data (didn't fix problem) |
16JD198 |
17JD199rain at mid-day |
18JD200Site Visit (SpB, AB, SD, SH, DB): Details , Photos (38) Span cylinder at 700 psi, N2 at 1810 psi for AP200: Span cylinder at 1750 psi, N2 at 250 psi changed the power source for the fast logger (now the fast channel is ok) DB added four meter teros11 tree water content sensors near the N Canopy tower at 11:30 MST, reduced the span/n2 cylinder pressures for the AP200 (to match flow/pressure during inlet sampling) SpB Jeep clear in AM; light rain at around noon |
19JD201 |
20JD202In Lab/Cristol (SpB, HR): Details , Photos (?) from 14:09--14:13 MST, sprayed water on the branch connected to load cell (still has needles, but they are brittle) |
21JD203hailstorm (at 11 MST) |
22JD204smoke/haze (from fires in CA, OR, Canada) |
23JD205smoke/haze (from fires in CA, OR, Canada) SpB Off |
24JD206 |
25JD207 |
26JD208 |
27JD209 |
28JD210 |
29JD211SpB Returns |
30JD212Site Visit (SpB, HR): Details , Photos (31) Span cylinder at 900 psi (closed main valve), N2 at 1810 psi for AP200: Span cylinder at 1850 psi, N2 at 300 psi from 9:42:15-9:44:15 MST, added 500 ml of water to pluvio1 from 9:45-9:47 MST, added 500 ml of water to pluvio2 from 10:14-10:25 MST swapped the 21.5m LI-7200 inlet (added the heated inlet, set to 2 Watts) at around 12 MST, swapped SD card from GPSCAM from 12:40-12:45 MST, swapped the location of pluvio1 with pluvio2 (and started using ucb_33.csi; consistent saving of pluvio1/2 variables) both tree sway sensors had no data (dead battery?) from 14:00-15:00 MST, moved ap200 temp sensors to new locations: #8 (21.5m), #7, #4, #5, #6, #3, #2, #1 (20 cm) Just-before we left, we decided to turn off the LI-6262 GAST pump SpB Prius very hot; smoke from the fires near Lyons, CO (Alexander Mountain and Stone Canyon Fires) are visible from the tower |
31JD213very hot; calm winds; smoke from CA/Canada and local fires |
1JD214more heat and smoke |
2JD215at 00:15 MST, lost network contact with the site (isffa); xcel power outage at 11:45 MST, power was restored; isffa came back up cleanly still more heat and smoke |
3JD216 |