NIWOT: Logbook Entries

NIWOT: To Do List Messages: 1 Entries..

Return to Logbook Contents Page
Entry Date Title Site Author #Graphics
4 Tue 11-Feb-2003To Do List from Feb 11, 2003.nonesburns


4: To Do List, Site none, Tue 11-Feb-2003 15:54:31 MST, To Do List from Feb 11, 2003.
Here is a list of items which Andy and I talked about:

Immediate Needs:
-----------------
At the tower :

Most Important :
(1) Download tower data loggers (Bill may have done this)
(2) Try loopback test on the quacker
(3) Check out the Kr hygrometer - is it hooked up properly. (at ~24m)
(4) Switch  PC-card in the MRStemp logger. Try to download data from old card.

Secondary Importance:
---------------------
(1) Calibrate the other CO2 standard at the trailer.  [still have 2-3 months 
      since the tank at the tower was full from last visit].
(2) Change filters on the profile system
(3) Change filters on the Li6262 EC system.

For Double Profiler :
(1) Buy new pump (big pump to continously pump the lines - check with tony and see what he ordered last summer).  Gast Model #RAA-V210-EB  (T-seed)
(2) Replumb the inlet lines at the shack.
        a) Put in bulkhead inlet with 3/8" bulkhead fittings
        b) make lines from bulkheads to glass volumes out of Dekabon.
        c) makes lines from glass volumes to solenoid manifolds out of Dekabon
(3) Need to order : 3/8" bulkhead fittings (14 or more) + some extra 3/8" ferrules and nuts.  [SpB, order from Denver valve]
(4) will probably need to change the inlet filters in the spring.


Stuff to order:
---------------
(1) new HMP45D Rel.Hum/Temp. sensor - need to ask : am replacing an HMP35D - will new one fit in the same housing???  [SpB.]

(2) Gast pump for EC system.  Model 1531.
  Can ask about repairing our old one - has a broken insert plate (part # AG293)
        (also buy a "Service Kit" - only about $25.00)
   [according to Dean this is not worth reparing].

(3) Get ATI sonic fixed. Make some plots of v-axis (vs. CSAT-3) from last summer to show them.  [T-seed]

(4) Send back propvane upstairs - had problem of suddenly not outputting analog signals, although it had power and good cables.  Could have been grounding problem.  Also, needed recalibration.  [T-seed]

(5) Send back Li7500 to have chopper blades painted.  [T-seed]


Computer Stuff:
--------------
(1) Buy new hard drive for  urquell (backup drive)
    [we decided that a 80Gb Drive for specialk might be a better thing to do].


Processing stuff:
----------------
(1) make ASCI outputs from Splus functions (in batchcode) so Sean can use in MatLab.
(2) get Matlab for the workstations.  [working on this...]
(3) get Linux and put it on Sean's PC.  [SpB.]



Stuff for Sean to know how to do:
--------------------------------
(1) Get Sean to run batch codes
(2) get Sean to run weekly/monthly code.
(3) put in soil data - from loggers to S+
(4) put in logger backup data.  [uses excel on PC].

(5) show him some Campbell logger code - how to do it.
     --to run here we need to bring the translator box back from the trailer
     --one idea:  change some of the code on quacker ch201 from "L" to "H" 
       resolution...also, update quacker:200 to use "campbell_binary". 

--some additional S-plus programs to try:  "co2.fluxes2.q" and "sonic.tests.q"