| Previous | Calendar |
March |
2026 |
Next | ||
|---|---|---|---|---|---|---|
| Sunday | Monday | Tuesday | Wednesday | Thursday | Friday | Saturday |
1JD60 |
2JD61 |
3JD62 |
4JD63Site Visit (SpB): Details , Photos (52) Span cylinder at 400 psi (closed valve), N2 at 350 psi (closed valve) for AP200: span cylinder at 1400 psi, N2 at 500 psi adjusted n2 delivery pressure/flow rate for AP200 batteries in RADCAM are dead (need to bring up new "C" ones) swapped batteries in the zentra/teros11 logger turned off the fans in the GAST pump box and LI-6262 enclosure Downloaded AP200, A Richardson, and teros11 tree water content logger data SpB Jeep Sunny, warm |
5JD64at around 16:30 MST, the 21.5m LI-7500RS/A (op2) and LI-7200 rebooted (likely power outage) |
6JD65snow |
7JD66 |
8JD67Change from MST to daylight savings time (MDT). |
9JD68 |
10JD69 |
11JD70high winds |
12JD71at around 4 MST, lost contact with the site at around 3:50 MST, the 21.5m LI-7500A (op2) and LI-7200 rebooted (likely power outage) at around 10 MST, reconnected to the site (likely a power outage) at around 14 MST, lost contact with the site (again) at around 14:08 MST, the 21.5m LI-7500RS/A (op2) and LI-7200 rebooted (likely power outage) at 14:00 MT, Lab Meeting (Nic) high winds |
13JD72No contact with the site (since the previous day) at around 14:30 MST, reconnected to the site (power restored) the 21.5m EOL csat3 did not come back up after power outage (down until power-cycled 3/28/16) there also appears to be something wrong with the LI-7200/7500A analog inputs into the fast cr23x? (also fixed on 3/28/16) |
14JD73at around 14:00 MST, the 21.5m LI-7500RS/A (op2) and LI-7200 rebooted (likely power outage) |
15JD74 |
16JD75CU Spring Break (starts) |
17JD76 |
18JD77 |
19JD78 |
20JD79CU Holiday (Spring Break) |
21JD80 |
22JD81 |
23JD82 |
24JD83 |
25JD84 |
26JD85at 14:00 MT, Lab Meeting (Sherrie) |
27JD86in AM: trees covered in ice/frost |
28JD87Site Visit (SpB): Details , Photos (46) Span cylinder at 400 psi (closed valve), N2 at 350 psi (closed valve) for AP200: span cylinder at ?? psi, N2 at ?? psi at 11:50 MST, power-cycled the EOL CSAT3 (worked ok after that) from 13:10-13:20 MST swapped the 21.5m LI-7200 inlet (2-micron filter had flow issues) from 14:40-14:50 MST re-swapped the 21.5m LI-7200 inlet using a 15-micron filter from 14:55-14:57 MST, cleaned krypton hygrometer tried to re-power the LI-6262, but the valves had issues unplugged the charger(s) connected to the deep-cycle batteries in the trailer Downloaded AP200 and teros11 tree water content logger data SpB Jeep Sunny, warm |
29JD88 |
30JD89Site Visit (SpB): Details , Photos (27) Span cylinder at 400 psi (closed valve), N2 at 350 psi (closed valve) for AP200: span cylinder at 1400 psi, N2 at 600 psi tried to restart the MET logger using met_12.csi (it would not compile) started using met_13.csi (removed all the LI-6262 calibration stuff) tried to re-power the LI-6262 (again), but the valves still had issues Downloaded A. Richardson logger data SpB Prius some clouds |
31JD90 |
1JD91 |
2JD92 |
3JD93 |